Part Number Hot Search : 
NJM2150V 150200 DT54F 100TS 00LVE 2SD18 1SS380TF AT43USB
Product Description
Full Text Search
 

To Download WPA60R48D1812-2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 wpa60 rev d th/smt 02/2004 product: www.cdpoweronline.com 60 watt dual output quarter brick dc/dc converter wpa60 series ? 2.3 x 1.45 x 0.40 (58.42mm x 36.83mm x 10.16mm) ? dual outputs - output 1/output 2 vdc: 1.5/1.0; 1.8/1.2; 2.2/1.5; 2.5/1.8; 3.3/1.2; 3.3/1.8; 3.3/2.5; 5.0/1.5; 5.0/3.3 ? through hole and smt models ? independently regulated outputs ? 36v - 75v input range ? industry standard pinouts ? input & output filtering ? remote on/off function ? meets basic insulation requirements of en60950 ? ul/cul 60950, vde en60950 approved ? fixed frequency operation ? no minimum load requirements ? output short circuit protection ? self-resetting over voltage protection ? c&d technologies, power electronics division is iso9001:2000 certi?ed corporate: www.cdtechno.com corporate: www.cdtechno.com product: www.cdpoweronline.com the wpa60 series are high performance dc/dc converters providing two independent regulated outputs. for maximum ?exibility, power can be traded between outputs as required. the unit delivers high performance across all line and load conditions. the wpa60 series are assembled by a fully automated process using surface mount components for increased reliability. wpa dc-dc converter modules are certi?ed to ul/cul 60950, and vde to en60950. it is designed to meet cispr22/en55022/fcc15j class b specs for emi levels with external ?ltering. other features include: ? fu ll regulation down to zero load ? undervoltage lock-out ? auto-start ? internal temperature shutdown ? auto-reset ? soft start ? remote on/off (available in positive or negative logic) ? short circuit protection ? overvoltage protection ? output voltage adj ust on both outputs nominal input output current typical voltage output output min max efficiency model (v dc ) #1 #2 load(a) load (a) (%) wpa60r48d1510* 48 1.5 1.0 0.0 12.0 2 82 wpa60r48d1812* 48 1.8 1.2 0.0 12.0 82 wpa60r48d2215* 48 2.2 1.5 0.0 12.0 86 wpa60r48d2518* 48 2.5 1.8 0.0 12.0 86 wpa60r48d3312* 48 3.3 1.2 0.0 12.0 89 wpa60r48d3318* 48 3.3 1.8 0.0 12.0 89 wpa60r48d3325* 48 3.3 2.5 0.0 12.0 89 wpa60r48d0515* 48 5.0 1.5 0.0 12.0 89 wpa60r48d0533* 48 5.0 3.3 0.0 12.0 90 input current at nominal input line = 1.45a (output power = 60w) *models available with -1 option (positive logic) 1 total output power not to exceed 60 watts 2 when the input voltage is less than 42 v dc the maximum allowable current on each output of the wpa60r48d 1510 is 6 a. product selection chart 1
2 wpa60 rev d th/smt 02/2004 product: www.cdpoweronline.com specifications, all models speci?cations are at t a = +25c, air?ow = 300lfm (1.5m/s) at nominal input voltage unless otherwise speci?ed. input parameter conditions min typ max units input voltage range vin = 48v, io=i rated 36 48 75 vdc re?ected ripple current 675 mapk-pk input control temperature shutdown pcb 120 c temperature hysteresis 5 c quiescent standby current vin = 48vdc 8 10 ma undervoltage lockout 32.5 v undervoltage shutdown 2 v general parameter conditions min typ max units isolation rated voltage 2000 vdc resistance 10 m ? capacitance 1000 pf leakage current 240 vac 90 arms output rated power 60 w voltage setpoint accuracy 1.5 % temperature coef?cient 0.005 % /c output voltage (over all conditions of i/p voltage v1 2 % of nom load & temperature) v2 8 % of nom ripple & noise (note 1) bw = 5hz to 20mhz 90 mvp-p output adjust range trim up 8 % trim down 5 % max capacitive load 10,000 f overvoltage protection 15 % general switching frequency 350 khz mttf per ml-hdbk-217 circuit stress method ground benign ta = +25 unmodi?ed database 1,000,000 hr package weight 30 g temperature operation/speci?cation pcb temperature -40 +100 c storage pcbtemperature -55 +125 c shutdown temperature pcb temperature +120 c note 1 : measured at 20 mhz bandwidth across a 6 f multi layer ceramic capacitor located approximately 1 from output terminals. specifications speci?cations are at t a = +25c, air?ow = 300lfm (1.5m/s) at nominal input voltage unless otherwise speci?ed.
3 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com to find model number model numbers part numbers wpa60r48d1510 6064965 wpa60r48d1812 6064957 wpa60r48d2215 6064956 wpa60r48d2518 6064955 wpa60r48d3312 6064953 wpa60r48d3318 6064952 wpa60r48d3325 6064951 wpa60r48d0515 6064966 wpa60r48d0533 6064954 wpa60r48d1510-1 6064993 wpa60r48d1812-1 6064992 wpa60r48d2215-1 6064991 wpa60r48d2518-1 6064990 wpa60r48d3312-1 6064989 wpa60r48d3318-1 6064988 wpa60r48d3325-1 6064987 wpa60r48d0515-1 6064994 wpa60r48d0533-1 6064986 ordering information (through hole) wpa60r48d yz - device family 60 watt, dual output, quarter brick, 48vdc input range model number selected from product selection chart (above) y = 15 = 1.5v, 18 = 1.8v, 22 = 2.2v, 25 = 2.5v, 33 = 3.3v, 05 - 5.0v, z = 10 = 1.0v, 12 = 1.2v, 15 = 1.5v, 18 - 1.8v 25 = 2.5v, 33 = 3.3v remote on/off logic and pin confguration no number = positive logic, through hole 1 = negative logic, through hole . 410 [ 10.41 ] max . 135 [ 3.43 ] . 188 [ 4.78 ] 3 2 1 4 5 6 7 . 350 [ 8.89 ] . 600 [ 15.2 4 ] . 850 [ 21.59 ] 1.100 [ 27.94 ] b o tt o m vie w ( pin side ) 2 .150 [ 54.6 1 ] . 150 [ 3.81 ] . 000 [ 0.00 ] .000 [ 0.00 ] 1. 0 7 5 [ 27.31 ] . 72 5 [ 18.42 ] 1.4 50 [ 36.83 .3 7 5 [ 9.52 ] 2. 30 0 .0 1 0 [ 58.4 2 . 25 ] ? . 040 [1.02] t yp ? . 060 [1.52] t yp dimensions are in inches [ mm ] mechanical (through hole) 1 +vin 2 remote on/off 3 -vin 4 +vout2 5 return 6 trim 7 +vout1 pin functions notes: pin placement tolerance: + .010 pin material: copper pin finish: matte tin over nickel converter weight: [24g] 1. certain early production units may use brass pins with a tin/lead over nickel finish 1 1
4 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com pin functions 1. +vin 2. remote on/off 3. -vin 4. +vout2 5. return 6. trim 7. +vout1 wpa60 3 2 1 4 5 6 7 .350 [8.89] .600 [15.24] .850 [21.59] 1.100 [27.94] bottom view (pin side) 2.150 [54.61] .150 [3.81] .000 [0.00] .000 [0.00] 1.075 [27.31] .725 [18.42] 1.450 .010 [36.83 .25] .375 [9.52] 2.300 .010 [58.42 .25] dimensions are in inches [mm] .410 [10.41] max .135 [3.43] ?.060 [1.52] typ to find model number model numbers part numbers wpa60r48d1510-2 wpa60r48d1510-2 WPA60R48D1812-2 WPA60R48D1812-2 wpa60r48d2215-2 wpa60r48d2215-2 wpa60r48d2518-2 wpa60r48d2518-2 wpa60r48d3312-2 wpa60r48d3312-2 wpa60r48d3318-2 wpa60r48d3318-2 wpa60r48d3325-2 wpa60r48d3325-2 wpa60r48d0515-2 wpa60r48d0515-2 wpa60r48d0533-2 wpa60r48d0533-2 wpa60r48d1510-3 wpa60r48d1510-3 wpa60r48d1812-3 wpa60r48d1812-3 wpa60r48d2215-3 wpa60r48d2215-3 wpa60r48d2518-3 wpa60r48d2518-3 wpa60r48d3312-3 wpa60r48d3312-3 wpa60r48d3318-3 wpa60r48d3318-3 wpa60r48d3325-3 wpa60r48d3325-3 wpa60r48d0515-3 wpa60r48d0515-3 wpa60r48d0533-3 wpa60r48d0533-3 ordering information (smt) wpa60r48d yz - device family 60 watt, dual output, quarter brick, 48vdc input range model number selected from product selection chart (above) y = 15 = 1.5v, 18 = 1.8v, 22 = 2.2v, 25 = 2.5v, 33 = 3.3v, 05 - 5.0v, z = 10 = 1.0v, 12 = 1.2v, 15 = 1.5v, 18 - 1.8v 25 = 2.5v, 33 = 3.3v remote on/off logic and pin configuration 2 = positive logic, smt 3 = negative logic, smt mechanical (smt) pin functions 1 +vin 2 remote on/off 3 -vin 4 +vout2 5 return 6 trim 7 +vout1 notes: pin placement tolerance: +.010 pin material: copper pin finish: matte tin over nickel with tin/lead coating on contact surface converter weight: [24g] * pin co-planarity within 0.004?
5 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com application notes output voltage trim each of the wpa60?s output voltages may be simulta- neously adjusted above or below the nominal set point by a value as indicated on the product data sheet. as shown in figure 1 , to raise the converter output voltage a resistor must be placed between the trim pin and return pin. figure 1 ? trim up circuit wpa60 trim return + vout1 + vout2 + vin on/off - vin (top view) r t r l1 r l2 to lower the converter output voltage a resistor must be placed between the trim pin and vout1 pin as shown in figure 2 . figure 2 ? trim down circuit wpa60 trim return + vout1 + vout2 + vin on/off - vin (top view) r t r l1 r l2 the resistance value required to achieve the desired amount of positive/negative trim can be determined by referring to the trim graph for each model. if trimming is not desired then the trim pin should be left uncon- nected. remote on/off function wpa60 trim return + vout1 + vout2 + vin on/off - vin (top view) control signal the wpa60 is equipped with a primary on/off pin used to remotely turn the converter on or off via a system signal. the input is ttl open-collector and/or fet open- drain compatible. for the positive logic model a system logic low signal will turn the unit off. for negative logic models a system logic high signal will turn the converter off. for negative logic models where no control signal will be used the on/off pin should be connected directly to ?vin to ensure proper operation. for positive logic models where no control signal will be used the on/off pin should be left open for normal operation. figure 3 ? remote on/off control circuit protective functions operation temperature shutdown the over temperature shutdown feature of the wpa60 will cause the unit to shutdown at a typical pwb temperature of 120 o c. this protective feature is comprised of a thermistor in the unit control loop. at a temperature of 120 o c this circuit will cause the pwm to go into an idle mode, resulting in no output from the converter and preventing damage to the converter components. when the temperature of the unit drops below 120 o c the fault condition will clear and the converter will resume normal operation. if the cause of the over temperature condition is not identified and corrected the unit will continue to cycle on and off.
6 wpa60 rev d th/smt 0 2/2004 product: www.cdpoweronline.com application notes input under-voltage shutdown the nominal input voltage for the wpa60 is 48vdc. at an input voltage of 32.5vdc nominal the unit will shutdown on an input under-voltage condition. at an input voltage less than 32.5v the under-voltage sensing circuit will send a signal to the pwm causing it to go into idle mode. this will result in no output from the converter, protecting the unit from a high input current condition. when the input voltage returns to a level above 32.5v the unit will return to normal operation. the unit will typically turn on at an input voltage of 34.5v nominal as indicated on the product data sheet. this is due to hysterisis designed into the protective circuit to prevent excessive cycling of the converter. output short circuit protection when a short circuit condition appears on the output the converter will go into hiccup mode. in hiccup mode the converter will cycle on and off repeate dly until the short circuit condition is cleared. safety the wpa60 meets safety requirements per ul/ cul 60950 and vde to en60950. additionally, the converter meets cispr22/ en55022/ fcc15j class b specs for emi levels with external ?ltering. performance characterization thermal derating maximum ouput current vs. ambient temperature at various air?ow rates has been determined for each model of the wpa60. from these graphs, the combination of maximum ambient temperature and minimum air?ow for select output current combinations can be determined. each model was analyzed for maximum allowable output power over an ambient temperature range of 0 to 85 o c and for air?ows up to 600lfm. in each case the maximum allowable power at a given air?ow and ambient temperature is de?ned as the point at which a known component reaches its individual temperature limit. ef?ciency ef?ciency data for each model was determined as a function of load current and input voltage. ef?ciency vs. load current was measured at an ambient temperature of 25 o c, an air?ow of 300lfm with an input voltage of 48vdc. ef?ciency vs. input voltage was measured at an ambient temperature of 25 o c, an air?ow of 300lfm and rated load. graphs for each model are provided in their respective section. s tart-up, on/off and transient response for each model, waveforms are provided showing output voltage response and timing to input voltage power up/down, remote on/off state change and load current transient responses. separate traces are provided showing the on/off timing sequence of the two outputs relative to one another. output voltage transient responses are provided for step load changes of 50% - 100% of rated load current and 100% - 50% of rated load. waveforms for each model are provided in their respective section.
7 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d0533 and wpa60r48d0533-1 84.00 85.00 86.00 87.00 88.00 89.00 90.00 91.00 92.00 12/0 10/3 8/6 6/9 4/12 0/12 load (v1/v2 amps) efficienc y 36v 48v 75v 88.00 88.20 88.40 88.60 88.80 89.00 89.20 89.40 89.60 89.80 90.00 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficienc y trim down graph trim up graph turn on time (v in to v out ) v 1 v 2 v in efficiency vs. input voltage @ t a = +25 0 c efficiency vs. output current @ t a = +25 0 c model wpa60r48d0533 rise time (v 1 and v 2 ) v 1 v 2 time scale = 500 s/div time scale = 50ms/div 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 70.75 33.95 20.05 14.00 10.55 8.15 6.45 5.20 4.20 3.40 2.80 2.25 1.75 1.40 1.02 0.77 trim resistance (kohms) change in vout (%) 5 vout 3.3 vout 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 147.95 73.60 48.15 35.20 27.30 22.06 18.25 15.40 13.15 11.35 trim resistance (kohms) change in vout (%) 5 vout 3.3 vout
8 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com turn off time (v in to v out ) v 1 v 2 v in v 1 v 2 on/off primary on time (primary remote to v out ) ch1 (5.0vdc) transient response 50% to 100% load step time scale = 10ms/div time scale = 500 s/div voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s v 1 i 1 ch1 (5.0vdc) transient response 100% to 50% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (3.3vdc) transient response 50% to 100% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 i 2 v 2 voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (3.3vdc) transient response 100% to 50% load step performance curves: wpa60r48d0533 and wpa60r48d0533-1
9 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 142.15 71.15 47.15 34.95 27.65 22.70 19.25 16.55 14.50 12.80 trim resistance (kohms) change in vout (% ) 5 vout 1.5 vout 84.60 84.80 85.00 85.20 85.40 85.60 85.80 86.00 86.20 86.40 86.60 86.80 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency performance curves: wpa60r48d0515 and wpa60r48d0515-1 model wpa60r48d0515 turn on time (v in to v out ) v 1 v 2 v in time scale = 50ms/div trim up graph trim down graph v 1 v 2 time scale = 1ms/div rise time (v 1 and v 2 ) efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c 76.00 78.00 80.00 82.00 84.00 86.00 88.00 90.00 92.00 12/0 11/3 10/6.6 8.4/12 6/12 3/12 012 load (v1/v2 amps) efficiency 36v 48v 75v 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 25.20 11.20 6.90 4.80 3.60 2.75 2.25 1.75 1.45 1.15 0.95 0.77 0.62 0.48 0.37 0.2 trim resistance (kohms) change in vout (% ) 5 vout 1.5 vout
10 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d0515 and wpa60r48d0515-1 turn off time (v in to v out ) v 1 v 2 v in time scale = 500 s/div primary on time (primary remote to v out ) v 1 v 2 on/off time scale = 2ms/div ch1 (5.0vdc) transient response 50% to 100% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch1 (5.0vdc) transient response 100% to 50% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.5vdc) transient response 50% to 100% load step voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.5vdc) transient response 100% to 50% load step i 2 v 2 i 2 v 2
11 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d3325 and wpa60r48d3325-1 trim up graph trim down graph turn on time (v in to v out ) v in v 1 v 2 time scale = 50ms/div v 1 v 2 time scale = 1ms/div rise time (v 1 and v 2 ) model wpa60r48d3325 efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c 84.00 85.00 86.00 87.00 88.00 89.00 90.00 91.00 92.00 12/0 5.5/7.2 5/6.6 10/11 9/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v 86.80 87.00 87.20 87.40 87.60 87.80 88.00 88.20 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 100.30 51.05 31.10 22.30 16.60 13.05 10.30 8.20 6.70 5.50 4.45 3.65 2.90 2.30 1.75 1.30 trim resistance (kohms) change in vout (% 3.3 vout 2.5 vout 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 218.65 106.00 66.75 48.40 36.80 29.60 24.15 20.30 17.15 14.70 trim resistance (kohms) change in vout (% ) 3.3 vout 2.5 vout
12 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d3325 and wpa60r48d3325-1 primary on time (primary remote to v out ) time scale = 2ms/div on/off v 2 v 1 turn off time (v in to v out ) v 1 v 2 v in time scale = 500 s/div ch1 (3.3vdc) transient response 50% to 100% load step voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 1 v 1 v 1 i 1 ch1 (3.3vdc) transient response 100% to 50% load step voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (2.5vdc) transient response 50% to 100% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 ch2 (2.5vdc) transient response 100% to 50% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2
13 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 1.00 2.00 3.00 4.00 5.00 6.00 213.50 108.00 70.10 52.65 41.45 34.00 28.45 24.25 20.95 18.50 trim resistance (kohms) change in vout (% ) 3.3v 1.8v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 95.45 41.30 24.05 16.75 12.25 9.50 7.45 6.00 4.80 4.00 3.10 2.55 1.95 1.60 1.20 0.8 7 trim resistance (kohms) change in vout (% 1.8v 3.3v 78.00 80.00 82.00 84.00 86.00 88.00 90.00 12/0 6/11 12/11.3 11.6/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v 84.20 84.40 84.60 84.80 85.00 85.20 85.40 85.60 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency performance curves: wpa60r48d3318 and wpa60r48d3318-1 efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c trim up graph trim down graph turn on time (v in to v out ) rise time (v 1 and v 2 ) time scale = 100ms/div time scale = 1ms/div v 1 v in v 1 v 2
14 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d3318 and wpa60r48d3318-1 turn off time (v in to v out ) v 1 v 2 v in time scale = 100 s/div primary on time (primary remote to v out ) v 1 v 2 on/off time scale = 2ms/div ch1 (3.3vdc) transient response 50% to 100% load step v 1 i 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch1 (3.3vdc) transient response 100% to 50% load step v 1 i 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.8vdc) transient response 50% to 100% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.8vdc) transient response 100% to 50% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 v 2 i 2
15 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 201.50 107.00 73.25 54.90 42.90 35.75 29.95 25.55 22.50 19.85 trim resistance (kohms) change in vout (% ) 3.3v 1.2v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 50.85 22.80 13.45 9.35 6.95 5.35 4.15 3.35 2.65 2.20 1.75 1.40 1.15 0.87 0.64 0.45 trim resistance (kohms) change in vout (% ) 3.3v 1.2v performance curves: wpa60r48d3312 and wpa60r48d3312-1 efficiency vs. input voltage @ t a = +25 0 c efficiency vs. output current @ t a = +25 0 c trim up graph trim down graph turn on time (v in to v out ) rise time (v 1 and v 2 ) time scale = 100ms/div time scale = 1ms/div v in v 1 v 2 v 1 v 2 74.00 76.00 78.00 80.00 82.00 84.00 86.00 88.00 90.00 92.00 12/0 12/6 12/12 6/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v 83.60 83.80 84.00 84.20 84.40 84.60 84.80 85.00 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency
16 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d3312 and wpa60r48d3312-1 turn off time (v in to v out ) time scale = 100 s/div v 1 v 2 v in primary on time (primary remote to v out ) v 1 v 2 on/off time scale = 2ms/div ch1 (3.3vdc) transient response 50% to 100% load step v 1 i 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch1 (3.3vdc) transient response 100% to 50% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.2vdc) transient response 50% to 100% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 ch2 (1.2vdc) transient response 100% to 50% load step v 2 i 2 voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s
17 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 74.00 76.00 78.00 80.00 82.00 84.00 86.00 88.00 90.00 92.00 12/0 12/6 6/12 12/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 90.30 42.55 29.10 20.05 15.45 11.85 9.70 7.65 6.40 5.05 trim resistance (kohms) change in vout (% ) 2.5 v 1.8 v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 92.40 38.60 22.75 15.75 11.15 8.75 6.55 5.20 3.95 3.20 2.40 1.90 1.30 0.91 0.49 0.20 trim resistance (kohms) change in vout (% 2.5v 1.8v 83.00 83.20 83.40 83.60 83.80 84.00 84.20 84.40 84.60 84.80 85.00 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficienc y performance curves: wpa60r48d2518 and wpa60r48d2518-1 efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c trim down graph trim up graph turn on time (v in to v out ) v in v 1 v 2 time scale = 100ms/div ch2 (1.8vdc) transient response 100% to 50% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s v 2 i 2
18 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d2518 and wpa60r48d2518-1 turn off time (v in to v out ) time scale = 500 s/div v 1 v 2 v in time scale = 2ms/div v 1 v 2 on/off primary on time (primary remote to v out ) ch1 (2.5vdc) transient response 50% to 100% load step voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s v 1 i 1 ch1 (2.5vdc) transient response 100% to 50% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.8vdc) transient response 50% to 100% load step i 2 v 2 voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.8vdc) transient response 100% to 50% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s v 2 i 2
19 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 91.80 49.10 32.15 23.30 18.00 13.70 10.85 8.85 7.75 6.40 trim resistance (kohms) change in vout (%) 2.2 v 1.5 v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 104.80 44.05 25.70 17.55 12.65 9.55 7.30 5.55 4.35 3.30 2.65 1.95 1.25 0.82 0.31 0.00 trim resistance (kohms) change in vout (%) 2.2 v 1.5 v 74.00 76.00 78.00 80.00 82.00 84.00 86.00 88.00 90.00 92.00 12/0 12/6 6/12 12/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v performance curves: wpa60r48d2215 and wpa60r48d2215-1 efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c trim up graph trim down graph turn on time (v in to v out ) v in v 1 v 2 time scale = 50ms/div rise time (v 1 and v 2 ) v 1 v 2 time scale = 1ms/div 82.40 82.60 82.80 83.00 83.20 83.40 83.60 83.80 84.00 84.20 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency
20 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d2215 and wpa60r48d2215-1 turn off time (v in to v out ) v 1 v 2 v in time scale = 500 s/div primary on time (primary remote to v out ) v 1 v 2 on/off time scale = 2ms/div ch1 (2.2vdc) transient response 50% to 100% load step v 1 i 1 voltage scale = 200mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch1 (2.2vdc) transient response 100% to 50% load step v 1 i 1 voltage scale = 200mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.5vdc) transient response 50% to 100% load step i 2 v 2 voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.5vdc) transient response 100% to 50% load step v 2 i 2 voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s
21 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 53.30 26.70 17.15 12.25 9.25 7.25 5.60 4.60 3.95 3.25 trim resistance (kohms) change in vout (%) 1.8v 1.2v 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 51.80 23.45 14.10 9.75 7.65 5.95 4.85 3.85 3.25 2.50 2.10 1.80 1.45 1.11 0.83 0.63 trim resistance (kohms) change in vout (%) 1.8v 1.2v 82.40 82.60 82.80 83.00 83.20 83.40 83.60 83.80 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency performance curves: wpa60r48d1812 and wpa60r48d1812-1 efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c trim up graph trim down graph turn on time (v in to v out ) time scale = 50ms/div v in v 1 v 2 rise time (v 1 and v 2 ) v 1 v 2 time scale = 1ms/div 74.00 76.00 78.00 80.00 82.00 84.00 86.00 88.00 90.00 92.00 12/0 12/6 6/12 12/12 0/12 load (v1/v2 amps) efficienc y 36v 48v 75v
22 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d1812 and wpa60r48d1812-1 turn off time (v in to v out ) v 1 v 2 v in time scale = 500 s/div primary on time (primary remote to v out ) on/off v 2 v 1 time scale = 5ms/div ch1 (1.8vdc) transient response 50% to 100% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch1 (1.8vdc) transient response 100% to 50% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.2vdc) transient response 50% to 100% load step voltage scale = 20mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 ch2 (1.2vdc) transient response 100% to 50% load step voltage scale = 20mv/div; time scale = 100 s/div di/dt = 0.2a/ s
23 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10.50 11.00 10.68 5.07 2.97 2.20 1.56 1.27 0.98 0.81 0.65 0.55 0.43 0.35 0.27 0.22 0.16 0.13 trim resistance (kohms) change in vout (%) 1.5 vout 1.0 vout 83.00 83.20 83.40 83.60 83.80 84.00 84.20 84.40 84.60 84.80 36 39 42 45 48 51 54 57 60 63 66 69 72 75 vin (vdc) efficiency 76.00 78.00 80.00 82.00 84.00 86.00 88.00 12/3 12/6 12/0 12/9 9/12 12/12 6/12 3/12 0/12 load (v1/v2 amps) efficiency 36v 48v 75v performance curves: wpa60r48d1510 and wpa60r48d1510-1 trim up graph trim down graph turn on time (v in to v out ) v in v 1 v 2 time scale = 50ms/div v 1 v 2 time scale = 1ms/div rise time (v 1 and v 2 ) efficiency vs. output current @ t a = +25 0 c efficiency vs. input voltage @ t a = +25 0 c 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 27.05 11.45 7.55 5.40 4.25 3.35 2.80 2.35 2.00 1.70 trim resistance (kohms) change in vout (%) 1.5 vout 1.0 vout
24 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com performance curves: wpa60r48d1510 and wpa60r48d1510-1 turn off time (v in to v out ) v 1 v 2 v in time scale = 500 s/div primary on time (primary remote to v out ) v 1 v 2 on/off time scale = 2ms/div ch1 (1.5vdc) transient response 50% to 100% load step i 1 v 1 voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 1 v 1 ch1 (1.5vdc) transient response 100% to 50% load step voltage scale = 100mv/div; time scale = 100 s/div di/dt = 0.2a/ s ch2 (1.0vdc) transient response 50% to 100% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2 ch2 (1.0vdc) transient response 100% to 50% load step voltage scale = 50mv/div; time scale = 100 s/div di/dt = 0.2a/ s i 2 v 2
25 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output current v/s tempe rature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 total output power (percent of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d0533) thermal derating (wpa60r48d0515) output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 ambient temperature (deg c) total output power (percent of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm
26 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 temperature (deg c) total output power (% of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating (wpa60r48d3325) thermal derating curves
27 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 temperature (deg c) total output power (% of rated) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d3318)
28 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 temperature (deg c) t o t a l o u t pu t p ower (% o f r a t e d) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d3312)
29 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 ambient temperature (deg c) total output power (% of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d2518)
30 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output curre nt v/s te mpe rature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 ambient temperature (deg c) total output power (% of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d2215)
31 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com thermal derating curves thermal derating (wpa60r48d1812) output current v/s temperature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 ambient temperature (deg c) total output power (% of rated ) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm
32 wpa60 rev d th/smt 2/2004 product: www.cdpoweronline.com output curre nt v/s te mpe rature vin = 48vdc 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 5 1525354555657585 ambient temperature (deg c) total output power (% of rated) 0 lfm 60 lfm 100 lfm 200 lfm 300 lfm 400 lfm 500 lfm 600 lfm thermal derating curves thermal derating (wpa60r48d1510) any data, prices, descriptions or specifications presented herein are subject to revision by c&d technologies, inc. without not ice. while such information is believed to be accurate as indicated herein, c&d technologies, inc. makes no warranty and hereby disclaims all warranties, express or impli ed, with regard to the accuracy or completeness of such information. further, because the product(s) featured herein may be used under conditions beyond its cont rol, c&d technologies, inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particula r use or in any specific application or arising from any course of dealing or usage of trade. the user is solely responsible for determining the suitability of the product(s) featured herein for user?s intended purpose and in user?s specific application. c&d technologies, inc. does not warrant or recommend that any of its products be used in a ny life support or aviation or aerospace applications. power electronics division, americas 3400 e britannia drive, tucson, arizona 85706 tel: 800.547.2537 fax: 520.295.4197 c&d technologies, emea/asia/pacific milton keynes mk14 5bu uk tel: +44 (0)1908 615232 fax: +44 (0)1908 617545


▲Up To Search▲   

 
Price & Availability of WPA60R48D1812-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X